Product Identification
Product ID:931-92,NON-ASBESTOS BRAKE LININGS
MSDS Date:01/09/1989
FSC:2530
NIIN:00-110-9606
MSDS Number: BPHXQ
Responsible Party
WINCHESTER, VA 22601-3250
US
Emergency Phone: 703-662-3842
Info Phone: 703-662-3871/703-665-2270
Preparer: M. K. LEUNG
Cage: 85117
Contractor
Telephone: 703-665-2270
Cage: 85117
Ingredients
GLASS FIBERS
OSHA PEL 10.0 MG/M3 (MFR)
ACGIH TLV: 10.0 MG/M3 (MFR)
SILICA, CRYSTALLINE - TRIPOLI
CAS: 1317-95-9
RTECS: VV7336000
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.1 MG/M3 RDUST;9293
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9293
PHENOLIC COMPOUND/PHENOLIC AND ELASTOMER COMPOUNDS
OSHA PEL 19.0 MG/M3 (MFR)
ACGIH TLV: 19.0 MG/M3 (MFR)
WOOD FLOUR/WOOD FLOUR AND OTHER FILLERS
OSHA PEL 1.0 MG/M3 (MFR)
ACGIH TLV: 1.0 MG/M3 (MFR)
IRON,ZINC,ALUMINUM,BRASS AND THEIR OXIDES
OSHA PEL 10 MG/M3 (MFR)
ACGIH TLV: 10 MG/M3 (MFR)
Hazards
LD50 LC50 Mixture:TLV FOR SILICA IS 0.1 MG/M3.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE & CHRONIC-SOME PERSONS MAY BE
SENSITIVE TO CASHEW RESINS & DEVELOP DERMATITIS-TYPE PROBLEMS.DUST
OF GLASS,SILICA,TALC,GRAPHITE,CARBON BLACK & COAL CAN PRODUCE
PNEUMOCONIOSIS & OTHER LUNG DAMAGE. METAL DUSTS CAN BE IRRITANTS OF
THE EYES & UPPER RESPIRATORY SYSTEM.THERE IS LITTLE EVIDENCE OF
HARM BY FE,AL,ZN DUSTS.
Explanation of Carcinogenicity:THE INTERNATIONAL AGENCY FOR RESEARCH ON
CANCER (IARC) HAS CLASSIFIED CERAMIC FIBERS,MINERAL WOOL AS
POSSIBLE CARCINOGEN
Effects of Overexposure:CASHEW RESINS-SKIN ERUPTIONS SIMILAR TO POISON
IVY. PNEUMOCONIOSIS-COUGHING,WHEEZING,SHORTNESS OF BREATH,IMPAIRED
PULMONARY FUNCTION.DUSTS IN EYE MAY CAUSE
IRRITATION.GASTROINTESTINAL DISTURBANCES POS SIBLE FROM
INGESTION.GLASS FIBER MAY CREATE TRANSIENT MECHANICAL IRRITATION OF
THE SKIN OF SOME PERSONS.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN
DISORDERS OR EYE PROBLEMS OR IMPAIRED RESPIRATORY FUNCTION MAY BE
MORE SUSCEPTIBLE TO THE EFFECTS OF THE SUBSTANCE.
First Aid
First Aid:GET MEDICAL ATTENTION IF NEEDED. SKIN:WASH WITH SOAP & WATER.
EYE:FLUSH WITH WATER FOR 15 MINUTES, HOLDING EYELIDS OPEN.
INHALED:REMOVE TO FRESH AIR. ORAL:CALL A PHYSICIAN.
Fire Fighting
Flash Point:NONE
Extinguishing Media:WATER (CLASS A, B, OR C)
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING AND
NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH FULL
FACEPIECE OPERATED IN THE POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:NONE KNOWN
Accidental Release
Spill Release Procedures:GRINDING, DRILLING, MILLING ETC. CAN RESULT IN
THE RELEASE OF AIRBORNE DUST. WEAR PROTECTIVE CLOTHING AND
NIOSH-APPROVED DUST RESPIRATOR. VACUUM OR WET SWEEP TO REMOVE
SPILLS. TRANSFER TO APPROPRIATE CONTAINERS FOR DISPOSAL. DO NOT
RAISE DUST.
Handling
Handling and Storage Precautions:STORAGE- STORE IN COOL PLACE. AVOID
GENERATING DUSTS.
Other Precautions:PRE-EMPLOYMENT SCREENING FOR ALLERGIES AND HISTORIES
OF SKIN SENSITIVITIES MAY BE BENEFICIAL IN DETERMINING PERSONS
SENSITIVE TO CASHEW MATERIALS.
Exposure Controls
Respiratory Protection:NIOSH-APPROVED FOR PNEUMOCONIOSIS-FIBROSIS
PRODUCING DUSTS AND DUSTS WITH TLV NOT LESS THAN 0.05 MG/M3.
Ventilation:LOCAL EXHAUST FOR DUST EXPOSURES EXCEEDING TLV.
Protective Gloves:RECOMMENDED
Eye Protection:RECOMMENDED FOR DUSTY CONDITIONS
Other Protective Equipment:LONG SLEEVE SHIRTS OR OTHER PROTECTIVE
CLOTHING, EYE BATH FOUNTAIN, QUICK EMERGENCY SHOWER.
Work Hygienic Practices:EMPLOYEES SHOULD BE PROPERLY INSTRUCTED IN THE
USE OF CONTROL MEASURES AS INDICATED ABOVE WHEN THERE IS A NEED FOR
IT.
Supplemental Safety and Health
AVOID SCRAPING OR SCRATCHING BRAKE LININGS OR OTHERWISE CREATING DUST
DURING ASSEMBLY. USE LOCAL EXHAUST VENTILATION AT ALL TIMES.
COMPRESSED AIR SHOULD NOT BE USED FOR CLEANING UP DUST FROM
LININGS. USE HEPA FILTERED VACUUM. USE BARRIER CREAMS FOR PERSONS
WITH SKIN SENSITIVE TO CASHEW RESINS AND FIBER GLASS.
Chemical Properties
HCC:N1
Spec Gravity:1.5 - 3.5
Solubility in Water:NO
Appearance and Odor:SOLID, DARK GREY COLOR, FRICTION MATERIAL ODOR
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.